78M6610+PSU Data Sheet
3.8
Command Register
The Command Register is located at address 0x00. Use this register to perform specific tasks such as
saving coefficients and some input registers into flash memory. It also allows issuing calibration
commands.
Save to Flash Command
Use the ACC command to save to flash the calibration coefficients and system defaults contained in the
some of the input registers. Upon reset or power-on, the values stored in flash will become new system
defaults.
The following table describes the ACC command bits:
Bit(s)
23:12
11:8
7:6
5
4:0
Value
0xACC
0x2
0x0
1
0x0
Description
“Access” Command.
2: Save Calibration to flash.
Not used.
Line Lock Bit.
Not used.
General Settings (Command 000)
The general settings command allows the user to enable functions such as UART auto reporting, relay
operations, and Line Lock mode etc.
Bit(s)
23:12
11
10
6
5
4
3
2
1:0
Rev 1
Value
0x00
0
T
FREQ
LL
TC
AR
AY
Description
“General settings” command.
Not Used
Stop temperature update: 1=stop; 0=update.
This bit prevents the firmware from overwriting the TempC (temperature result)
register. This is necessary when supplying a known temperature for calibration.
Stop Frequency update 1=stop; 0=update.
This bit stops the update of Freq used by the sine/cosine generator for
fundamental and harmonic measurements. It is the unscaled value of
Frequency with 8 integer and 16 fraction bits. The user can set the fundamental
frequency when FREQ is set.
Line Lock 1= lock to line cycle; 0= independent.
This bit selects the accumulation interval (computation cycle) mode. If not
locked the computation is executed over a fixed number of samples (high rate)
contained in the Accum register. If locked, the computation is executed over a
number of samples accumulation interval.
Enable Gain/Temperature compensation 1=enable; 0=disable.
This bit allows the firmware to modify the system gain based on measured
temperature.
Enable Auto Reporting 1=enable; 0=disable.
This bit enables auto reporting mode on UART. The user or host can also set or
clear this command bit, enabling or disabling auto reporting.
Enable Autonomous Relay operation 1=enable; 0=disable/normal mode.
This bit enables autonomous relay operation. The user or host can also set or
clear this command bit, enabling or disabling autonomous operation.
Not used
37
相关PDF资料
78M6612-DB/OMU-USB KIT DEMO OUTLET MEASUREMENT OMU1
78M6612-EVM-1 BOARD EVAL 78M6612 AC-PMON
78M6613-EVM-1 EVAL BOARD 78M6613
78M6613-SP-1 EVAL KIT 78M6613-SP-1
78M6618-PDU1 BOARD EVAL 78M6618 PDU1
78M6631-EVM-1 EVAL BOARD 78M6631
78P2351R-DB BOARD DEMO FOR 78P2351R
79-WHITE-1"X60YD TAPE GLASS CLOTH 1"X 60YD WHT
相关代理商/技术参数
78M6610+PSUEVK1# 制造商:Maxim Integrated Products 功能描述:ENERGY MEASUREMENT PROCESSOR EV KIT FOR SINGLE-PHASE POWER-S - Boxed Product (Development Kits) 制造商:Maxim Integrated Products 功能描述:EVAL KIT 78M6610+PSU
78M6610LMU 制造商:MAXIM 制造商全称:Maxim Integrated Products 功能描述:Energy Measurement Processor for Load Monitoring Units
78M6611-EVM 制造商:Maxim Integrated Products 功能描述:78M6611 EVAL BOARD - Boxed Product (Development Kits)
78M6611-IVT/F 功能描述:IC POWER MEASUREMENT AC 24-TSSOP RoHS:是 类别:集成电路 (IC) >> PMIC - 能量测量 系列:* 产品培训模块:Lead (SnPb) Finish for COTS Obsolescence Mitigation Program 标准包装:2,500 系列:*
78M6611-IVT/F/P 制造商:Maxim Integrated Products 功能描述:PROGRAMMED - LEAD FREE - Rail/Tube
78M6611-IVTR/F 功能描述:IC POWER MEASUREMENT AC 24-TSSOP RoHS:是 类别:集成电路 (IC) >> PMIC - 能量测量 系列:* 产品培训模块:Lead (SnPb) Finish for COTS Obsolescence Mitigation Program 标准包装:2,500 系列:*
78M6611-IVTR/F/P 制造商:Maxim Integrated Products 功能描述:PROGRAMMED - LEAD FREE/TAPE & REEL - Tape and Reel
78M6612 制造商:MAXIM 制造商全称:Maxim Integrated Products 功能描述:Single-Phase, Dual-Outlet Power and Energy Measurement IC